Instructions for
Calibrating the
iSavi
Terminal
Vedere la pagina 0
1 2 3 4 5 6 7 8 9

Sommario

Pagina 1

Ver : 1.0 Date : 13 November 2014 Instructions for Calibrating the iSavi™ Terminal

Pagina 2 - Contents

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 2 Contents Introduction 3 Procedure

Pagina 3

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 3 Introduction Your iSavi™ satellite terminal is specially designe

Pagina 4

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 4 5. Connect to your iSavi™ over Wi-Fi by selecting the iSavi™ S

Pagina 5

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 5 6. Click on Settings and select Calibration from the drop down

Pagina 6

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 6 8. Rotate your terminal in a clockwise direction around the Y-

Pagina 7

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 7 10. Rotate your terminal in a clockwise direction around the X

Pagina 8

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 8 13. Once the verification is completed, check that the message

Pagina 9 - Contact Details

Instructions for Calibrating the iSavi™ Terminal © Addvalue Innovation Pte Ltd 9 Contact Details Addvalue Innovation Pte Ltd Technical / Custome